Language selection

Search


Perkins

List of Engines

Engine Manufacturer: Perkins
Engine Model: 1106D-E66TA/C6.6 (2558/2200) (PDF, 56 kb)
Governing Standard: CSA M424.2-90 (Non-Gassy Mines)

Certificate Number Engine Rating and Measured Fuel Rate at Sea Level Sulphur in Fuel - %wt. Ventilation Prescription*
CFM m3/min
1199 196 HP @ 2,200 RPM, 78.4 lb/hr 0.05 19,600 555.0
0.10 20,900 591.8
0.20 23,600 668.3
0.25 25,000 707.9
0.50 31,700 869.3

* These CSA ventilation rates are suitable for low sulphur fuel if permitted by the appropriate regulatory authority.


Engine Manufacturer: Perkins
Engine Model: 1106D-E66TA/C6.6 (3418/2200) (PDF, 55 kb)
Governing Standard: CSA M424.2-90 (Non-Gassy Mines)


Certificate Number
Engine Rating and Measured Fuel Rate at Sea Level Sulphur in Fuel - %wt. Ventilation Prescription*
CFM m3/min
1200 182 HP @ 2,200 RPM, 69.5 lb/hr 0.05 15,900 450.2
0.10 17,100 484.2
0.20 19,500 552.2
0.25 20,700 586.2
0.50 26,600 753.2

* These CSA ventilation rates are suitable for low sulphur fuel if permitted by the appropriate regulatory authority.


Engine Manufacturer: Perkins
Engine Model: PERK 1206E-E70TTA, CAT C7.1 (3708/2100), Tier 4i – 120M2 Motor Grader
Submitted by: Underground Force, LLC
Governing Standard: CSA M424.2-90 (Non-Gassy Mines)

Certificate Number Engine Rating and
Fuel Rate at Sea Level
Sulphur in
Fuel - ppm
Ventilation Prescription*
CFM m3/s
1256 192 HP (143 kW) @ 2100 RPM, 78.9 lb/h 15 11,400 5.38
24,700+ 11.66+

* This engine requires ultra low sulphur (< 15 ppm) fuel
+ These ventilation rates are recommended by CanmetMINING where some of the gases govern ventilation rates rather than the EQI criterion.


Engine Manufacturer: Perkins
Engine Model: 404D-22/C2.2 (GN51/3000) (PDF, 55 kb)
Governing Standard: CSA M424.2-90 (Non-Gassy Mines)


Certificate Number
Engine Rating and Measured Fuel Rate at Sea Level Sulphur in Fuel - %wt. Ventilation Prescription*
CFM m3/min
1201 51 HP @ 3,000 RPM, 23.6 lb/hr 0.05 5,900 167.1
0.10 6,200 175.6
0.20 6,700 189.7
0.25 7,100 201.1
0.50 9,100 257.6

* These CSA ventilation rates are suitable for low sulphur fuel if permitted by the appropriate regulatory authority.

Page details