Performance Directory of Solar Domestic Hot Water Systems
Disclaimer
This directory is generated for informational purposes only and does not necessarily reflect the views of the Government of Canada nor constitute an endorsement of any commercial product or person. Neither Canada nor its ministers, officers, employees or agents makes any warranty in respect of this directory or assumes any liability arising out of this directory.
Background
This directory provides potential buyers with independent data on the thermal performance of solar domestic hot water systems that are designed for residential use. The thermal performance is an important factor in the purchase decision since the water heating capacity can vary between systems. However, actual thermal energy output will vary depending on hot water usage, geographical location, and several system installation and operating parameters. Energy output is not the only criteria for selecting a solar domestic hot water system. The cost, expected service life (and warranty), quality of installation, availability of parts and quality of service are also important factors.
All systems listed in this directory have completed certification to CSA Standard F379 "Solar Domestic Hot Water Systems". The ratings in this directory have been determined using the standard day specified in that Standard for the 300 litres/day hot water load. For system models that were not tested, detailed computer models were developed and the standard day test was simulated using TRNSYS software.
Certified Solar Domestic Hot Water Systems (modified 9 May 2014)
Make | Foot note | Model | Annual Performance Rating |
Collectors Number & Size |
Collector Type |
System Type / Tank Volume |
Heat Exchanger Type |
---|---|---|---|---|---|---|---|
Apricus Inc. |
1 |
APSS_CLOSED _DWBPHE _AP40 |
7.13 GJ/y | 2 x 2.74 m² | ETC AP-20 | Solar Preheat 303 L |
Double Wall |
Atis Group | 1, 2 | Solensis ST-0100 | 5.27 GJ/y | 1 x 2.874 m² | Flat Plate Solensis- TL-ST-01 |
Solar Preheat 272 L |
Single Wall |
1 | Solensis ST-0200 | 8.69 GJ/y | 2 x 2.874 m² | Flat Plate Solensis - TL-ST-01 |
Solar Preheat 272 L |
Single Wall |
|
Bosch Thermotechnology Corp. |
1 | FKT (3) OEM Electric S12 | 8.93 GJ/y | 3 x 2.38 m² | Flat Plate FKT-1S |
Solar Plus Supplemental 454 L |
Double Wall |
Copperhill Alternate Energy Inc. |
2 | CETT-32-08-CP-06 | 3.09 GJ/y | 1 x 3.43 m² | ETC CETT-32-08 |
Solar Preheat 155 L |
Single Wall |
CETT-32-08-CP-06 | 6.35 GJ/y | 2 x 3.43 m² | ETC CETT-32-08 |
Solar Preheat 155 L |
Single Wall |
||
Dimplex North America Ltd. | ESSW2 | 6.67 GJ/y | 2 X 2.02 m2 | Flat Plate DSCA-2M | Solar Preheat 200 L |
Single Wall | |
ESDW2 | 6.00 GJ/y | 2 X 2.02 m2 | Flat Plate DSCA-2M | Solar Preheat 200 L |
Double Wall | ||
EnCom Alternative Energy Solutions Ltd. |
EnCom 300 | 6.85 GJ/y | 1 x 4.69 m² | ETC TZ58/1800 -30R |
Solar Preheat 300 L |
Single Wall |
|
Enerworks Inc. | 1, 2 | EWRA 1 | 5.27 GJ/y | 1 x 2.874 m² | Flat Plate COL-4x8-TL -SG1-SD10 |
Solar Preheat 272 L |
Single Wall |
1 | EWRA 2 | 8.69 GJ/y | 2 x 2.874 m² | Flat Plate COL-4x8-TL -SG1-SD10 |
Solar Preheat 272 L |
Single Wall |
|
1, 2 | EWRA2-DWHX | 8.33 GJ/y | 2 x 2.874 m² | Flat Plate COL-4x8-TL -SG1-SD10 |
Solar Preheat 272 L |
Double Wall |
|
Globe Solar Energy Inc. |
3 | IP-195 | 3.34 GJ/y | 1 x 2.55 m² | ICS ETC 24-tube |
Solar Preheat 155 L |
Single Wall |
Heliodyne Inc. | 1, 2 | 50185 | 3.28 GJ/y | 1 x 2.51 m² | Flat Plate GOBI 406 001 |
Solar Preheat 227 L |
Double Wall |
1 | 50186 | 6.00 GJ/y | 2 x 2.51 m² | Flat Plate GOBI 406 001 |
Solar Preheat 303 L |
Double Wall |
|
NY Thermal Inc. | 2 | SRT-Pk1 | 7.98 GJ/y | 2 x 2.15 m2 | Flat Plate SRT-215 | Solar Preheat 300 L |
Single Wall |
SRT-Pk2 | 10.46 GJ/y | 3 x 2.15 m2 | Flat Plate SRT-215 | Solar Preheat 450 L |
Single Wall | ||
Solaris Manufacturing Inc. | 4 | DBPro-1m300dw5 | 3.08 GJ/y | 1 X 2.03 m2 | Flat Plate BluTec-2M | Solar Preheat 300 L |
Double Wall |
2, 4 | DBPro-2m300dw5 | 4.80 GJ/y | 2 X 2.03 m2 | Flat Plate BluTec-2M | Solar Preheat 300 L |
Double Wall | |
2, 4 | DBPro-3m300dw5 | 6.12 GJ/y | 3 X 2.03 m2 | Flat Plate BluTec-2M | Solar Preheat 300 L |
Double Wall | |
Solcan Ltd. | 5 | DBTT 64-40 | 7.58 GJ/y | 2 x 2.89 m² | Flat Plate 2101 |
Solar Preheat 136 L |
Single Wall |
Thermodynamics Ltd. |
1, 2 | SB32-9PV | 6.00 GJ/y | 1 x 2.98 m2 | Flat Plate S-32 |
Solar Preheat 270 L |
Single Wall |
1 | SB64-9PV | 9.94 GJ/y | 2 x 2.98 m² | Flat Plate S-32 |
Solar Preheat 270 L |
Single Wall |
|
Viessmann Manufacturing Company Inc. |
2 | 1-200F-200V | 5.07 GJ/y | 1 x 2.53 m2 | Flat Plate Vitosol 200-F |
Solar Preheat 200 L |
Single Wall |
2-200F-300V | 8.51 GJ/y | 2 x 2.53 m² | Flat Plate Vitosol 200-F |
Solar Preheat 300 L |
Single Wall |
Footnotes:
- Must be used with CSA approved water tank for solar heat storage.
- Simulated
- For use above -10 C (seasonal operation); not eligible for ecoENERGY Retrofit - Homes
- Drainback solar storage tank
- The system also includes a drainback volume of 23 L
Download a copy of the table (PDF, 48 KB).
Requirements for Inclusion in the Performance Directory
Systems must be certified to CSA Standard F379. To have your system listed, please contact the Directory Coordinator.
Links
- ecoENERGY Retrofit – Homes - Certain solar domestic hot water systems are eligible under the ecoENERGY Retrofit – Homes program. Only products purchased after June 6, 2011, and installed after a pre-retrofit evaluation are eligible for a federal grant.
- ENERGY STAR® in Canada
ENERGY STAR® helps consumers quickly and easily identify major appliances and other energy-using equipment that save energy. Solar domestic water heaters sold in Canada may qualify. - Canadian Solar Industries Association (CANSIA)
CANSIA is an association for solar manufacturers, installers, resellers, and consultants. They offer a member industry directory, as well as a listing of certified solar hot water installers across Canada. - Exova
Formerly Bodycote Testing Group, Exova houses Canada’s National Solar Test Facility (NSTF), for testing and rating of solar technologies under controlled sunlight, temperature, and wind.
- Date modified: